The CF-11 external rotor centrifugal fan is an efficient, low-noise, and low-energy consumption fan product. It adopts an external rotor motor design, with a compact structure and stable air flow. It is widely used in various high-end buildings, hotels, ships, and basements for exhaust, dust removal, and ventilation needs. It can also be used in supporting projects for refrigeration equipment. There are various models of CF-11 fans, including CF-11 (W) 1.5 # to CF-11 (W) 3 #, with a power range of 240W to 830W and a speed of up to 1310r/min to 2650r/min. In addition, the CF-11 fan has the characteristics of long service life and is suitable for various occasions such as households, canteens, and small boilers
It is widely applicable to the needs of various types of high-end buildings, hotels, factories, mines, ships and basements for ventilation and ventilation. It can also be used for supporting engineering of refrigeration equipment.
Model | Voltage
(V) |
Current
(A) |
Power
(W) |
Capacity
(μF) |
Speed
(rpm) |
Flow volume
(m3/h) |
Total pressure
(Pa) |
Decibel
(dB)
|
CF-11(W)1.5# | 220 | 1.1 | 240 | 5 | 2650 | 600 | 480 | <70 |
CF-11(W)1.5# | 380 | 0.55 | 240 | 5 | 2650 | 600 | 480 | <70 |
CF-11(W)2# | 220 | 1.08 | 235 | 8 | 1400 | 930 | 400 | <70 |
CF-11(W)2# | 380 | 0.65 | 220 | 8 | 1400 | 930 | 400 | <70 |
CF-11(W)2.5# | 220 | 2.2 | 480 | 12 | 1400 | 2010 | 490 | <75 |
CF-11(W)2.5# | 380 | 1.2 | 385 | 12 | 1400 | 2010 | 490 | <75 |
Model | A | B | C | D | E | F | G | H | I |
1.5# | 240 | 280 | 90 | 130 | 110 | 88 | 88 | 110 | 130 |
2# | 330 | 380 | 135 | 180 | 160 | 130 | 155 | 180 | 200 |
2.5# | 390 | 460 | 135 | 180 | 160 | 130 | 160 | 190 | 210 |
The installation of the external rotor centrifugal fan CF-11 should follow professional guidelines. Firstly, ensure that the installation environment meets the equipment requirements and check if the fan components are complete and undamaged. Then, assemble according to the installation drawings and instructions, paying special attention to adjusting the coaxiality of the fan shaft and motor shaft to ensure smooth operation of the fan. During the installation process, it is necessary to fix the fan in the reserved position and calibrate the levelness. When connecting pipelines, ensure that the joints are leak free, and electrical connections should be completed by professional electricians. Finally, conduct a trial run to check if the fan is operating normally. Please strictly follow the manufacturer’s requirements and local safety regulations during installation to ensure the safe and efficient operation of the fan.
Zhejiang Shuntong Electric Co., Ltd. was established in 2009, specializing in the production of various high and low voltage complete sets of equipment.
Copyright ©2024 Zhejiang Shuntong Electric Co., Ltd., All rights reserved. Powered by VNT